Proportional Controlled PLC Type High Pressure LPG/Air Mixer

Description

DIVISION LOW PRESSURE MEDIUM PRESSURE
Design Pressure 0.99MPa 0.99MPa
LPG Pressure 0.2~0.3MPa 0.2~0.3MPa
AIR Pressure ATM 0.07MPa
Mixed Gas Pressure ~0.04MPa 0.04~0.1MPa
Mixed Gas Calorie(MIN) 12,500kcal/Nm3 000kcal/Nm3

 

HIGH PRESSURE LPG+Air MIXER(SNG BLANDER) SPECIFICATION
– 
LPG Mixing Ration (Butane 80%, Propane 20%), Nixing Gas Pressure: 15Psig,
Minimum Air Pressure : 7bar, Minimum LPG Pressure : 25Psig

Model Capacity LPG
Regulator
Air
Regulator
LPG
Flowrater
Air
Flowrater
LPG
Control
Valve
Air
Control
Valve
SNG
Line
Size
Air Line
Chegk
Valve
Air Surge
Tank
Capacity
(M3)
SNG Surge
Tank
Capacity
(M3)
JHM-25 10mmbtu/hr 2″ 1″ 1″ 1″ 1″ 1″ 2″ 1-1/2″ 0.47 0.28
JHM-40 20mmbtu/hr 2″ 1″ 1-1/2″ 1-1/2″ 1-1/2″ 1-1/2″ 3″ 2″ 0.93 0.56
JHM-50 30mmbtu/hr 2″ 1″ 1-1/2″ 1-1/2″ 2″ 2″ 4″ 3″ 1.40 0.84
JHM-65 40mmbtu/hr 2″ 2″ 2″ 2″ 2-1/2″ 2-1/2″ 4″ 3″ 1.86 1.12
JHM-80 50mmbtu/hr 2″ 2″ 2″ 2″ 2-1/2″ 2-1/2″ 5″ 3″ 2.33 1.40
60mmbtu/hr 2″ 2″ 2″ 2″ 3″ 3″ 5″ 4″ 2.79 1.68
70mmbtu/hr 2″ 2″ 2-1/2″ 2-1/2″ 3″ 3″ 5″ 4″ 3.25 1.97
80mmbtu/hr 2″ 2″ 3″ 3″ 3″ 3″ 6″ 4″ 3.72 2.25
90mmbtu/hr 2″ 2″ 3″ 3″ 3″ 3″ 6″ 4″ 4.18 2.53
100mmbtu/hr 2″ 2″ 3″ 3″ 3″ 3″ 6″ 4″ 4.65 2.81
110mmbtu/hr 2″ 2″ 3″ 3″ 3″ 3″ 6″ 4″ 5.12 3.09